Multichem® S Plus (Barcoded for Alinity c Systems)
Increase laboratory efficiencies with barcoded QC - Reduce handling time, reclaim storage space, reduce lot evaluation time, reduce packaging waste, reduce dead-volume waste with Multichem S Plus - consolidated third-party clinical chemistry QC material. This third party control material is available from your local Abbott Diagnostics office.
Resources:
BrochureProduct Description
Technopath Clinical diagnostics is the exclusive manufacturer of onboard third party qc materials for the Abbott Alinity platforms. Multichem S Plus (Barcoded for Alinity c Systems) is the only multianalyte chemistry control available on the market that can be stored onboard the Alinity c. Multichem S Plus Control is intended for use as a third party, multi-constituent quality control material to monitor the precision of laboratory testing procedures for Chemistry Assays. It incorporates serum chemistry, immunology, lipid, TDM , enzymes and esoterics.
Multichem S Plus contains 105 analytes including the addition of C-Reactive Protein and Rheumatoid Factor at clinically relevant concentrations. NOTE: This is the main difference between Multichem S Plus and our other ‘regular’ Multichem S product, i.e that CRP and RF are added to the Multichem S Plus product only. Also includes Chemistry, Esoterics, Immunoproteins, Enzymes, Lipids, and Therapeutic Drugs.
Multichem S Plus is designed as a tri-level, liquid stable frozen product. This product will typically be run after reagent calibration and at a frequency dictated by laboratory QC procedures and reagent / instrument manufacturer instructions. The product should be treated the same as patient specimens and run in accordance with the instructions accompanying the instrument, kit or reagent being used. The control should be stored at -20°C to –80°C and thawed as per IFU prior to use. The product should be stored at 2 to 8°C between use.
Benefits
On-board storage on the Alinity system in temperature controlled reagent carousel
Automatically run at user-defined intervals
Barcoded vials make loading faster and easier - minimizing errors
On-board stability is monitored by the Alinity system software
Features
Frozen liquid stable, tri-level control
10 days open vial stability once thawed and stored at 2 to 8 degrees
28 months shelf life once stored at -20 to -80°C degrees
5 day onboard stability
Third party independent quality control
Analyte List
Acetaminophen*
Acid Phosphatase*
Activated Alanine Aminotransferase (AALT)
Activated Aspartate Aminotransferase (AAST)
ADNase B (Anti-Streptococcal DNase B)*
Alanine Aminotransferase (ALT)
Albumin BCG
Albumin BCP
Alkaline Phosphatase (ALkP)
Alpha Hydroxybutyrate Dehydrogenase*
Alpha-1 Acidglycoprotein
Alpha-1 Antitrypsin
Alpha-2-Macroglobulin*
Amikacin
Amylase
Amylase Pancreatic
Angiotensin Converting Enzyme*
Anti-streptolysin O (ASO)*
Antithrombin III*
Apolipoprotein A1
Apolipoprotein B
Aspartate Aminotransferase (AST)
Beta -2 Microglobulin*
Beta Hydroxybutyrate Dehydrogenase*
Bile Acids
Bilirubin Indirect*
Bilirubin, Direct
Bilirubin, Total
C1 Inhibitor*
Caffeine*
Calcium
Calcium Ionized*
Carbamazepine
Carbon Dioxide (Bicarbonate)
Ceruloplasmin*
CH50 (Total hemolytic Complement)*
Chloride
Cholesterol HDL
Cholesterol LDL
Cholesterol Total
Cholinesterase*
Complement C3
Complement C4
Copper*
Cortisol*
C-Reactive Protein
Creatine Kinase (CK)
Creatinine Enzymatic
Creatinine Picrate
Cystatin C*
Digoxin
Ethanol
Ferritin*
Fructosamine*
Gamma Glutamyltransferase
Gentamicin
Glucose
Haptoglobin
Hemopexin*
IgE*
IgG1, Subclass*
IgG2, Subclass*
IgG3, Subclass*
IgG4, Subclass*
Immunoglobulin A
Immunoglobulin G
Immunoglobulin M
Iron
Kappa Light Chain*
Lactate
Lactate Dehydrogenase (LDH)
Lambda Light Chain*
Lipase*
Lipoprotein (a)*
Lithium
Magnesium
Osmolality*
Phenobarbital
Phenytoin
Phosphorous
Potassium
Prealbumin
Properdin Factor B*
Prostatic Acid Phosphatase*
Protein Electrophoresis*
Protein, Total
Retinol Binding Protein*
Rheumatoid Factor
Salicylate
Sodium
sTfR (Soluble Transferrin Receptor)*
Theophylline*
Thyroxine, Total (TT4)*
Tobramycin*
Total Iron Binding Capacity*
Transferrin
Triglycerides
Triiodothyronine, Total (TT3)*
Unsaturated Iron Binding Capacity (UIBC)
Urea Nitrogen
Uric Acid
Valproic Acid*
Vancomycin
Zinc*
*Please refer to lot specific package inserts for stability and performance claims.
Ordering
Name
Description
Kit
Part Code
Multichem S Plus - Alinity
Assayed Single Level (Level 1)
12 x 5mL
08P88-10
Multichem S Plus - Alinity
Assayed Single Level (Level 2)
12 x 5mL
08P88-11
Multichem S Plus - Alinity
Assayed Single Level (Level 3)
12 x 5mL
08P88-12
Multichem S Plus - Alinity
Unassayed Single Level (Level 1)
12 x 5mL
08P87-10
Multichem S Plus - Alinity
Unassayed Single Level (Level 2)
12 x 5mL
08P87-11
Multichem S Plus - Alinity
Unassayed Single Level (Level 3)
12 x 5mL
08P87-12
Name
Multichem S Plus - Alinity
Description
Assayed Single Level (Level 1)
Kit
12 x 5mL
Part Code
08P88-10
Name
Multichem S Plus - Alinity
Description
Assayed Single Level (Level 2)
Kit
12 x 5mL
Part Code
08P88-11
Name
Multichem S Plus - Alinity
Description
Assayed Single Level (Level 3)
Kit
12 x 5mL
Part Code
08P88-12
Name
Multichem S Plus - Alinity
Description
Unassayed Single Level (Level 1)
Kit
12 x 5mL
Part Code
08P87-10
Name
Multichem S Plus - Alinity
Description
Unassayed Single Level (Level 2)
Kit
12 x 5mL
Part Code
08P87-11
Name
Multichem S Plus - Alinity
Description
Unassayed Single Level (Level 3)
Kit
12 x 5mL
Part Code
08P87-12
Contact your local Abbott office to place an order or contact us to learn more
Instructions For Use (IFU)
Instructions For Use (IFU)
Log in to our Technical Library to access Instructions for Use (IFU), Data Sheets and XML files.
Technical LibraryFind a product by analyte, instrument, partcode or name
Why Technopath
Technopath was the first company in the world to develop truly consolidated third party quality controls for hospital laboratories.
Through the benefits of test consolidated QC, Technopath’s Multichem® customers have increased their laboratory efficiencies and reduced the cost of their quality control program.
Our Clients
Sign up to our newsletter for the latest updates
Be one of the first to receive news from Technopath Clinical Diagnostics.