Multichem® IA Plus (distributed by Abbott)

Increase laboratory efficiencies - Reduce handling time, reclaim storage space, reduce lot evaluation time, reduce packaging waste, reduce dead-volume waste with Multichem IA Plus - consolidated Third Party immunoassay QC material. This third party control material is available from your local Abbott Diagnostics office.

Multichem IA Plus in laboratory technologist's hand

Product Description

Multichem IA Plus Control is intended for use as a third party, multi-constituent quality control material to monitor the precision of laboratory testing procedures for Immunoassay Assays. Multichem IA Plus contains 86 analytes including fertility and thyroid hormones, steroid hormones, cardiac markers, anaemia markers, therapeutic drugs, adrenal markers, bone metabolism markers and tumour markers.

Multichem IA Plus is designed as a tri-level, liquid stable frozen product. This product will typically be run after reagent calibration and at a frequency dictated by laboratory QC procedures and reagent / instrument manufacturer instructions. The product should be treated the same as patient specimens and run in accordance with the instructions accompanying the instrument, kit or reagent being used. The control is to be stored at -20°C to –80°C and thawed as per IFU prior to use. The product are to be stored at 2 to 8°C between use.

Show

Benefits

Reduced QC packaging, storage and inventory management

Unique level of test consolidation

Reduced operator handling hours

Reduced dead volume and general waste output

Satisfies regulatory guidelines for use of independent controls

Concentrations targeted at clinically relevant values

Long shelf life extends lot availability

Features

Frozen, Liquid stable, tri-level control

10 days open vial stability once thawed and stored at 2 to 8 degrees

28 months shelf life once stored at -20 to -80°C degrees

Third party independent quality control

Optimised and assayed for Abbott Architect and Alinity systems

Human based materials used as part of manufacturing process

Mimics performance of commutable patient samples

Analyte List

17-Hydroxyprogesterone*

25-OH Vitamin D

Acetaminophen*

Adrenocorticotrophic Hormone (ACTH)*

Aldosterone*

Alpha Fetoprotein (AFP)

Amikacin*

Androstenedione*

Angiotensin*

Anti-thyroglobulin

Anti-thyroperoxidase

BNP (1-32)

CA 125

CA 15-3

CA 19-9

Caffeine*

Calcitonin*

Carbamazepine

Carbamazepine, Free*

Carcinogenic Embryonic Antigen (CEA)

Chloramphenicol*

CK-MB

Cortisol

C-Peptide

Cyclosporine*

DHEA-Sulfate

Digoxin

Disopyramide*

EPO*

Estradiol

Estriol, Free*

Estriol, Total*

Estrogen, Total*

Ethosuximide*

Ferritin

Folate

Follicle Stimulating Hormone (FSH)

Gentamicin

High Sensitive Troponin I

Homocysteine

Human Chorionic Gonadotropin (BhCG)

Human Growth Hormone*

Ibuprofen*

Immunoglobulin E

Insulin

Insulin Like Growth Factor (IgF-1)*

Lidocaine*

Lithium*

Luteinizing Hormone

Myoglobin

N-Acetyl procainamide*

NT Pro-BNP*

Ostase*

Intact Parathyroid Hormone (PTH) (1-84)

Intact Parathyroid Hormone (PTH) (1-84) (STAT)

Phenobarbital

Phenytoin

Phenytoin, Free*

Primidone*

Procainamide*

Procollagen NP Type 1*

Progesterone

Prolactin

Prostate Specific Antigen, Free

Prostate Specific Antigen, Total

Quinidine*

Renin*

Salicylate*

Sex Hormone Binding Globulin

Testosterone

Testosterone, Free*

Theophylline

Thyroglobulin*

Thyroid Stimulating Hormone (TSH)

Thyroxine Binding Globulin*

Thyroxine, Free (FT4)

Thyroxine, Total (TT4)

Tobramycin*

Triiodothyronine, Free (FT3)

Triiodothyronine, Total (TT3)

Troponin I

Troponin T*

T-Uptake

Ultra Sensitive CRP*

Valproic Acid

Valproic Acid, Free*

Vancomycin

Vitamin B12

*Please refer to lot specific package inserts for stability and performance claims.

Ordering

Name

Description

Kit

Part Code

Multichem IA Plus

Assayed (Tri-Level) - ordered via your local Abbott office.

3 x 4 x 5mL

05P76-10

Name

Multichem IA Plus

Description

Assayed (Tri-Level) - ordered via your local Abbott office.

Kit

3 x 4 x 5mL

Part Code

05P76-10

Contact your local Abbott office to place an order or contact us to learn more

Instructions For Use (IFU)

Multichem IA Plus Instructions for Use

Instructions For Use (IFU)

Log in to our Technical Library to access Multichem IA Plus Instructions for Use (IFUs), Data Sheets and XML files (Abbott users).

Technical Library

Find a product by analyte, instrument, partcode or name

Why Technopath

Technopath was the first company in the world to develop truly consolidated third party quality controls for hospital laboratories.

Through the benefits of test consolidated QC, Technopath’s Multichem® customers have increased their laboratory efficiencies and reduced the cost of their quality control program.

Discover More

Our Clients

The main driver for change was a mandate to consolidate and improve workflow efficiencies. Reduced physical cost, coupled with a reduction in staff time, proved significant.

Blackrock Clinic Dublin - Eoin O’Rourke, Head of Pathology, Blackrock Clinic Ltd., Blackrock, Co. Dublin, Ireland

In 2017, Technopath signed a global agreement with Beckman Coulter Diagnostics.

"Technopath’s highly efficient QC solution will help Beckman Coulter customers address the strong and growing demand for multi-constituent quality control products, and meets the requirements of lab accreditation."

John Blackwood - Senior Vice President of Products and Services at Beckman Coulter.

Sign up to our newsletter for the latest updates

Be one of the first to receive news from Technopath Clinical Diagnostics.